Proline Promass Q 300 Coriolis Flowmeter
Brand: Endress+Hauser AGDoes not ship to OH, United States
Promass Q 300 provides the highest measurement accuracy for mass flow, volume flow and density. Being the preferred choice for custody transfer applications, it has also been optimized for liquid applications where entrained gas is known to be present.
The compact transmitter offers high flexibility in terms of operation and system integration: access from one side, remote display and improved connectivity options. Heartbeat Technology ensures compliance and process safety at all times.
- Measuring principle operates independently of physical fluid properties such as viscosity or density
- Highest measurement performance for custody transfer, density and under tough process conditions
Device properties
- Mass flow: measurement error ±0.05 % (PremiumCal)
- Density: measurement error ±0.2 kg/m3
- High turndown due to low pressure loss/zero point
- Compact dual-compartment housing with up to 3 I/Os
- Backlit display with touch control and WLAN access
- Remote display available
- Secured measuring quality – unmatched accuracy of mass flow, volume flow and density
- Optimized performance for liquids with entrained gas – MFT (Multi-Frequency Technology)
- Fewer process measuring points – multivariable measurement (flow, density, temperature)
- Space-saving installation – no in/outlet run needs
- Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses
- Reduced complexity and variety – freely configurable I/O functionality
- Integrated verification – Heartbeat Technology
Displaying prices & availability for Ohio, United States in USD. Change location.
Featured
- Featured
- Quantity In Stock
- Price
- SKU / Model Number
Models matching criteria: 14
Promass Q 300, 8Q3B1F, DN150 6", Non-hazardous Area view more
- Preselection - Promass Q 300, 8Q3B1F, DN150 6"
- Approval, Transmitter + Sensor - Non-hazardous Area
- Power Supply - 100-230 Vac/24 Vdc
- Output; Input 1 - 4-20 mA HART
- Output; Input 2 - W/O
- Output; Input 3 - W/O
- Display; Operation - 4-line Illum., Touch Control
- Housing - Alu, Coated
- Electrical Connection Thread - NPT 1/2
- Meas. Tube Material, Wetted Parts Surface - Stainless Steel, Not Polished
- Process Connection - Cl.150 RF, 1.4404/316/316L, Flange ASME B16.5
- Calibration Flow - 0.10% Mass 5-point, Traceable ISO/IEC 17025
- Device Model - 2
- Options - No
4 In Stock
Does not ship to OH, United States
Log In to See Pricing
Promass Q 300, 8Q3B80, DN80 3", ATEX+IECEx; Z0/1, Z21, Ex de IIB/IIIC view more
- Preselection - Promass Q 300, 8Q3B80, DN80 3"
- Approval, Transmitter + Sensor - ATEX+IECEx; Z0/1, Z21, Ex de IIB/IIIC
- Power Supply - 100-230 Vac/24 Vdc
- Output; Input 1 - 4-20 mA HART
- Output; Input 2 - W/O
- Output; Input 3 - W/O
- Display; Operation - 4-line Illum., Touch Control
- Housing - Alu, Coated
- Electrical Connection Thread - NPT 1/2
- Meas. Tube Material, Wetted Parts Surface - Stainless Steel, Not Polished
- Process Connection - Cl.150 RF, 1.4404/316/316L, Flange ASME B16.5
- Calibration Flow - 0.10% Mass 5-point, Traceable ISO/IEC 17025
- Device Model - 2
- Options - No
4 In Stock
Does not ship to OH, United States
Log In to See Pricing
Promass Q 300, 8Q3B1H, DN100 4", Non-hazardous Area view more
- Preselection - Promass Q 300, 8Q3B1H, DN100 4"
- Approval, Transmitter + Sensor - Non-hazardous Area
- Power Supply - 100-230 Vac/24 Vdc
- Output; Input 1 - 4-20 mA HART
- Output; Input 2 - W/O
- Output; Input 3 - W/O
- Display; Operation - 4-line Illum., Touch Control
- Housing - Alu, Coated
- Electrical Connection Thread - NPT 1/2
- Meas. Tube Material, Wetted Parts Surface - Stainless Steel, Not Polished
- Process Connection - Cl.150 RF, 1.4404/316/316L, Flange ASME B16.5
- Calibration Flow - 0.10% Mass 5-point, Traceable ISO/IEC 17025
- Device Model - 2
- Options - No
3 In Stock
Does not ship to OH, United States
Log In to See Pricing
Promass Q 300, 8Q3B80, DN80 3", Non-hazardous Area view more
- Preselection - Promass Q 300, 8Q3B80, DN80 3"
- Approval, Transmitter + Sensor - Non-hazardous Area
- Power Supply - 100-230 Vac/24 Vdc
- Output; Input 1 - 4-20 mA HART
- Output; Input 2 - W/O
- Output; Input 3 - W/O
- Display; Operation - 4-line Illum., Touch Control
- Housing - Alu, Coated
- Electrical Connection Thread - NPT 1/2
- Meas. Tube Material, Wetted Parts Surface - Stainless Steel, Not Polished
- Process Connection - Cl.150 RF, 1.4404/316/316L, Flange ASME B16.5
- Calibration Flow - 0.10% Mass 5-point, Traceable ISO/IEC 17025
- Device Model - 2
- Options - No
3 In Stock
Does not ship to OH, United States
Log In to See Pricing
Promass Q 300, 8Q3B2H, DN200 8", ATEX+IECEx; Z0/1, Z21, Ex de IIB/IIIC view more
- Preselection - Promass Q 300, 8Q3B2H, DN200 8"
- Approval, Transmitter + Sensor - ATEX+IECEx; Z0/1, Z21, Ex de IIB/IIIC
- Power Supply - 100-230 Vac/24 Vdc
- Output; Input 1 - 4-20 mA HART
- Output; Input 2 - W/O
- Output; Input 3 - W/O
- Display; Operation - 4-line Illum., Touch Control
- Housing - Alu, Coated
- Electrical Connection Thread - NPT 1/2
- Meas. Tube Material, Wetted Parts Surface - Stainless Steel, Not Polished
- Process Connection - Cl.150 RF, 1.4404/316/316L, Flange ASME B16.5
- Calibration Flow - 0.10% Mass 5-point, Traceable ISO/IEC 17025
- Device Model - 2
- Options - No
3 In Stock
Does not ship to OH, United States
Log In to See Pricing
Promass Q 300, 8Q3B2H, DN200 8", Non-hazardous Area view more
- Preselection - Promass Q 300, 8Q3B2H, DN200 8"
- Approval, Transmitter + Sensor - Non-hazardous Area
- Power Supply - 100-230 Vac/24 Vdc
- Output; Input 1 - 4-20 mA HART
- Output; Input 2 - W/O
- Output; Input 3 - W/O
- Display; Operation - 4-line Illum., Touch Control
- Housing - Alu, Coated
- Electrical Connection Thread - NPT 1/2
- Meas. Tube Material, Wetted Parts Surface - Stainless Steel, Not Polished
- Process Connection - Cl.150 RF, 1.4404/316/316L, Flange ASME B16.5
- Calibration Flow - 0.10% Mass 5-point, Traceable ISO/IEC 17025
- Device Model - 2
- Options - No
2 In Stock
Does not ship to OH, United States
Log In to See Pricing
Promass Q 300, 8Q3B2F, DN250 10", ATEX+IECEx; Z0/1, Z21, Ex de IIB/IIIC view more
- Preselection - Promass Q 300, 8Q3B2F, DN250 10"
- Approval, Transmitter + Sensor - ATEX+IECEx; Z0/1, Z21, Ex de IIB/IIIC
- Power Supply - 100-230 Vac/24 Vdc
- Output; Input 1 - 4-20 mA HART
- Output; Input 2 - W/O
- Output; Input 3 - W/O
- Display; Operation - 4-line Illum., Touch Control
- Housing - Alu, Coated
- Electrical Connection Thread - NPT 1/2
- Meas. Tube Material, Wetted Parts Surface - Stainless Steel, Not Polished
- Process Connection - Cl.150 RF, 1.4404/316/316L, Flange ASME B16.5
- Calibration Flow - 0.10% Mass 5-point, Traceable ISO/IEC 17025
- Device Model - 2
- Options - No
2 In Stock
Does not ship to OH, United States
Log In to See Pricing
Promass Q 300, 8Q3B2F, DN250 10", Non-hazardous Area view more
- Preselection - Promass Q 300, 8Q3B2F, DN250 10"
- Approval, Transmitter + Sensor - Non-hazardous Area
- Power Supply - 100-230 Vac/24 Vdc
- Output; Input 1 - 4-20 mA HART
- Output; Input 2 - W/O
- Output; Input 3 - W/O
- Display; Operation - 4-line Illum., Touch Control
- Housing - Alu, Coated
- Electrical Connection Thread - NPT 1/2
- Meas. Tube Material, Wetted Parts Surface - Stainless Steel, Not Polished
- Process Connection - Cl.150 RF, 1.4404/316/316L, Flange ASME B16.5
- Calibration Flow - 0.10% Mass 5-point, Traceable ISO/IEC 17025
- Device Model - 2
- Options - No
1 In Stock
Does not ship to OH, United States
Log In to See Pricing
Promass Q 300, 8Q3B50, DN50 2", Non-hazardous Area view more
- Preselection - Promass Q 300, 8Q3B50, DN50 2"
- Approval, Transmitter + Sensor - Non-hazardous Area
- Power Supply - 100-230 Vac/24 Vdc
- Output; Input 1 - 4-20 mA HART
- Output; Input 2 - W/O
- Output; Input 3 - W/O
- Display; Operation - 4-line Illum., Touch Control
- Housing - Alu, Coated
- Electrical Connection Thread - NPT 1/2
- Meas. Tube Material, Wetted Parts Surface - Stainless Steel, Not Polished
- Process Connection - Cl.150 RF, 1.4404/316/316L, Flange ASME B16.5
- Calibration Flow - 0.10% Mass 5-point, Traceable ISO/IEC 17025
- Device Model - 2
- Options - No
1 In Stock
Does not ship to OH, United States
Log In to See Pricing
Promass Q 300, 8Q3B50, DN50 2", ATEX+IECEx; Z0/1, Z21, Ex de IIB/IIIC view more
- Preselection - Promass Q 300, 8Q3B50, DN50 2"
- Approval, Transmitter + Sensor - ATEX+IECEx; Z0/1, Z21, Ex de IIB/IIIC
- Power Supply - 100-230 Vac/24 Vdc
- Output; Input 1 - 4-20 mA HART
- Output; Input 2 - W/O
- Output; Input 3 - W/O
- Display; Operation - 4-line Illum., Touch Control
- Housing - Alu, Coated
- Electrical Connection Thread - NPT 1/2
- Meas. Tube Material, Wetted Parts Surface - Stainless Steel, Not Polished
- Process Connection - Cl.150 RF, 1.4404/316/316L, Flange ASME B16.5
- Calibration Flow - 0.10% Mass 5-point, Traceable ISO/IEC 17025
- Device Model - 2
- Options - No
1 In Stock
Does not ship to OH, United States
Log In to See Pricing
Promass Q 300, 8Q3B25, DN25 1", ATEX+IECEx; Z0/1, Z21, Ex de IIB/IIIC view more
- Preselection - Promass Q 300, 8Q3B25, DN25 1"
- Approval, Transmitter + Sensor - ATEX+IECEx; Z0/1, Z21, Ex de IIB/IIIC
- Power Supply - 100-230 Vac/24 Vdc
- Output; Input 1 - 4-20 mA HART
- Output; Input 2 - W/O
- Output; Input 3 - W/O
- Display; Operation - 4-line Illum., Touch Control
- Housing - Alu, Coated
- Electrical Connection Thread - NPT 1/2
- Meas. Tube Material, Wetted Parts Surface - Stainless Steel, Not Polished
- Process Connection - Cl.150 RF, 1.4404/316/316L, Flange ASME B16.5
- Calibration Flow - 0.10% Mass 5-point, Traceable ISO/IEC 17025
- Device Model - 2
- Options - No
1 In Stock
Does not ship to OH, United States
Log In to See Pricing
Promass Q 300, 8Q3B1F, DN150 6", ATEX+IECEx; Z0/1, Z21, Ex de IIB/IIIC view more
- Preselection - Promass Q 300, 8Q3B1F, DN150 6"
- Approval, Transmitter + Sensor - ATEX+IECEx; Z0/1, Z21, Ex de IIB/IIIC
- Power Supply - 100-230 Vac/24 Vdc
- Output; Input 1 - 4-20 mA HART
- Output; Input 2 - W/O
- Output; Input 3 - W/O
- Display; Operation - 4-line Illum., Touch Control
- Housing - Alu, Coated
- Electrical Connection Thread - NPT 1/2
- Meas. Tube Material, Wetted Parts Surface - Stainless Steel, Not Polished
- Process Connection - Cl.150 RF, 1.4404/316/316L, Flange ASME B16.5
- Calibration Flow - 0.10% Mass 5-point, Traceable ISO/IEC 17025
- Device Model - 2
- Options - No
1 In Stock
Does not ship to OH, United States
Log In to See Pricing
Promass Q 300, 8Q3B25, DN25 1", Non-hazardous Area view more
- Preselection - Promass Q 300, 8Q3B25, DN25 1"
- Approval, Transmitter + Sensor - Non-hazardous Area
- Power Supply - 100-230 Vac/24 Vdc
- Output; Input 1 - 4-20 mA HART
- Output; Input 2 - W/O
- Output; Input 3 - W/O
- Display; Operation - 4-line Illum., Touch Control
- Housing - Alu, Coated
- Electrical Connection Thread - NPT 1/2
- Meas. Tube Material, Wetted Parts Surface - Stainless Steel, Not Polished
- Process Connection - Cl.150 RF, 1.4404/316/316L, Flange ASME B16.5
- Calibration Flow - 0.10% Mass 5-point, Traceable ISO/IEC 17025
- Device Model - 2
- Options - No
Out of Stock
Does not ship to OH, United States
Log In to See Pricing
Promass Q 300, 8Q3B1H, DN100 4", ATEX+IECEx; Z0/1, Z21, Ex de IIB/IIIC view more
Preselection - Promass Q 300, 8Q3B1H, DN100 4"
Approval, Transmitter + Sensor - ATEX+IECEx; Z0/1, Z21, Ex de IIB/IIIC
Power Supply - 100-230 Vac/24 Vdc
Output; Input 1 - 4-20 mA HART
Output; Input 2 - W/O
Output; Input 3 - W/O
Display; Operation - 4-line Illum., Touch Control
Housing - Alu, Coated
Electrical Connection Thread - NPT 1/2
Meas. Tube Material, Wetted Parts Surface - Stainless Steel, Not Polished
Process Connection - Cl.150 RF, 1.4404/316/316L, Flange ASME B16.5
Calibration Flow - 0.10% Mass 5-point, Traceable ISO/IEC 17025
Device Model - 2
Options - No
3 - 6 weeks
Does not ship to OH, United States
Log In to See Pricing
Specifications
Brand
Measuring Principle
- Coriolis
Product Headline
- Innovative Specialist for challenging applications with a compact, easily accessible transmitter
- Highest measurement performance for custody transfer, density and under tough process conditions
Sensor Features
- Optimized performance for Liquids with entrained gas - MFT (Multi-Frequency Technology)
- Fewer process measuring points - multivariable measurement (Flow, density, Temperature)
- Space-saving installation - no in-/outlet run needs
- Mass flow: measurement error ± 0.05 % (PremiumCal)
- Density: measurement error ± 0.2 kg/m³
- High turndown due to Low Pressure loss/zero point
Transmitter Features
- Full access to process and diagnostic information - numerous, freely combinable I/Os and fieldbuses
- Reduced complexity and variety - freely configurable I/O functionality
- Integrated Verification - Heartbeat Technology
- Compact Dual-Compartment housing with up to 3 I/Os
- Backlit display with touch Control and WLAN access. Remote display available
Nominal Diameter Range
- DN 25 to 250 (1 to 10")
Wetted Materials
- Measuring Tube: 1.4404 (316/316L) Stainless Steel for cryogenic applications
- Connection: 1.4404 (316/316L)
Measured variables
- Mass Flow
- Density
- Temperature
- Volume Flow
- Corrected Volume Flow
- Reference Density
- Concentration
Maximum Measurement Error
- Mass flow (Liquid): ± 0.10 % (Standard), 0.05 % (Option)
- Volume flow (liquid): ± 0.10 %
- Mass flow (Gas): ± 0.25 %
- Density (Liquid): ± 0.2 kg/m³ (standard), ± 0.1 kg/m³ (option)
Measuring Range
- 0 to 240,000 kg/h (0 to 88,183 lb/min)
Maximum Process Pressure
- PN 100, Class 600, 63K
Medium Temperature Range
- Option: -196° to +150° C (-321° to +302° F)
- Standard: -50° to +205° C (-58° to +401° F)
Ambient Temperature Range
- Option: -50° to +60° C (-58° to +140° F)
- Standard: - 40° to +60° C (-40° to +140° F)
Sensor Housing Material
- 1.4404 (316L), Highest corrosion resistance
Transmitter Housing Material
- AlSi10Mg, Coated, 1.4409 (CF3M) similar to 316L Stainless Steel for hygenic transmitter Design
Degree of Protection
- IP66/67
- Type 4X Enclosure
- IP69
Display/Operation
- 4-line backlit display with touch Control (Operation from outside)
- Configuration via local display and Operating tools possible
- Remote display available
Outputs
- 3 outputs
- 4-20 mA HART (Active/passive)
- 4-20 mA WirelessHART
- 4-20 mA (Active/Passive)
- Pulse/frequency/switch output (Active/passive)
- Double pulse output (Active/passive)
- Relay Output
Inputs
- Status Input
- 4-20 mA Input
Digital Communication
- HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS-485, PROFINET, PROFINET over Ethernet-APL, EtherNet/IP, OPC-UA
Power Supply
- DC 24 V
- AC 100 to 230 V
- AC 100 to 230 V / DC 24 V (non-hazardous area)
Hazardous Area Approvals
- ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC
Product Safety
- CE, C-tick, EAC Marking
Functional Safety
- According to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological Approvals and Certificates
- Calibration performed on accredited calibration facilities (acc. to ISO /IEC 17025)
- Heartbeat Technology complies with the Requirements for measurement traceability according to ISO 9001: 2015 - Section 7.1.5.2 a (TÜV SÜD attestation)
- MI-005 Liquids other than water (Hydrocarbons, Liquified gases, Cryogenic Liquids)
- OIML R117 (Liquids other than water, Liquified Gases, Cryogenic Liquids)
- NTEP (Liquids other than water, Cryogenic Liquids)
- MC (Liquids other than water, Cryogenic Liquids)
Marine Approvals and Certificates
- LR approval, DNV approval, ABS approval, BV approval, CCS approval
Pressure Approvals and Certificates
- PED, CRN, AD 2000
Material Certificates
- 3.1 material
- NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK
Hygienic Approvals and Certificates
- 3-A, EHEDG, cGMP